HDPE

Urecon Pre-Insulated HDPE Core Pipe DR 32.5
Dimensions 19 mm (¾ in) to 500 mm (20 in)

Nominal
Pipe Size
Outside
Pipe Dia.
Insulation O.D. DR 32.5, 345 kPa (50 psi)
Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
19 CTS ¾ CTS SEE DR-11
25 CTS 1 CTS SEE DR-11
40 1.5 SEE DR-17
50 2 SEE DR-17
75 3 SEE DR-26
100 4 SEE DR-26
150 6 168 6.625 247 9.75 279 11.00 157.2 6.19 5.0 0.20 4.24 2.85
200 8 219 8.625 304 12.00 336 13.25 204.7 8.06 6.6 0.26 6.59 4.43
250 10 273 10.75 355 14.00 393 15.50 255.2 10.05 8.4 0.33 9.57 6.43
300 12 324 12.75 406 16.00 438 17.50 302.7 11.92 9.9 0.39 12.83 8.62
350 14 355 14.00 438 17.25 476 18.75 332.49 13.09 10.92 0.43 18.10 12.16
400 16 406 16.00 N/A N/A 527 20.75 379.98 14.96 12.45 0.49 22.13 14.87
450 18 457 18.00 N/A N/A 597 23.50 427.48 16.83 13.97 0.55 26.57 17.85
500 20 508 20.00 N/A N/A 635 25.00 474.98 18.70 15.75 0.62 31.70 21.30
  1. Other sizes and metric dimensional pipe available on request.
  2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
  3. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
  4. Jacketing 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
  5. Pressure rating of DR 32.5 is 345 kPa (50 psi) at 23°C (73.4°F).
  6. Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
  7. Insulation cut back for standard butt fused joint is 230 mm (9 in); other cut backs available on request. Call your Urecon representative to discuss your application requirements.
  8. Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
  9. Data may vary slightly from one pipe manufacturer to another.
  10. Reference specifications (core pipe): see pipe specifications.

Urecon Pre-Insulated HDPE Core Pipe DR 26
Dimensions 19 mm (¾ in) to 500 mm (20 in)

Nominal
Pipe Size
Outside
Pipe Dia.
Insulation O.D. DR 26, 441 kPa (64 psi)
Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
19 CTS ¾ CTS SEE DR-11
25 CTS 1 CTS SEE DR-11
40 1.5 SEE DR-17
50 2 SEE DR-17
75 3 88 3.50 171 6.75 196 7.75 81.50 3.21 3.56 0.14 1.89 1.27
100 4 114 4.50 196 7.75 228 9.00 104.90 4.13 4.32 0.17 2.77 1.86
150 6 168 6.625 247 9.75 279 11.00 154.43 6.08 6.60 0.26 4.88 3.28
200 8 219 8.625 304 12.00 336 13.25 201.17 7.92 8.38 0.33 7.68 5.16
250 10 273 10.75 355 14.00 393 15.50 250.70 9.87 10.41 0.41 11.27 7.57
300 12 324 12.75 406 16.00 438 17.50 297.43 11.71 12.45 0.49 15.21 10.22
350 14 355 14.00 438 17.25 476 18.75 326.64 12.86 13.72 0.54 21.53 14.47
400 16 406 16.00 N/A N/A 527 20.75 373.38 14.70 15.75 0.62 26.48 17.79
450 18 457 18.00 N/A N/A 597 23.50 419.86 16.53 17.53 0.69 32.10 21.57
500 20 508 20.00 N/A N/A 635 25.00 466.60 18.37 19.56 0.77 38.40 25.80
  1. Other sizes and metric dimensional pipe available on request.
  2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
  3. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
  4. Jacketing 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
  5. Pressure rating of DR 26 is 441 kPa (64 psi) at 23°C (73.4°F).
  6. Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
  7. Insulation cut back for standard butt fused joint is 230 mm (9 in); other cut backs available on request. Call your Urecon representative to discuss your application requirements.
  8. Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
  9. Data may vary slightly from one pipe manufacturer to another.
  10. Reference specifications (core pipe): see pipe specifications.

Urecon Pre-Insulated HDPE Core Pipe DR 21
Dimensions 19 mm (¾ in) to 500 mm (20 in)

Nominal
Pipe Size
Outside
Pipe Dia.
Insulation O.D. DR 21, 552 kPa (80 psi)
Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
19 CTS ¾ CTS SEE DR-11
25 CTS 1 CTS SEE DR-11
40 1.5 SEE DR-17
50 2 SEE DR-17
75 3 88 3.50 171 6.75 196 7.75 80.01 3.15 4.06 0.16 2.09 1.41
100 4 114 4.50 196 7.75 228 9.00 102.87 4.05 5.33 0.21 3.11 2.09
150 6 168 6.625 247 9.75 279 11.00 151.38 5.96 7.87 0.31 5.62 3.78
200 8 219 8.625 304 12.00 336 13.25 196.85 7.75 10.41 0.41 8.94 6.01
250 10 273 10.75 355 14.00 393 15.50 245.36 9.66 12.95 0.51 13.24 8.89
300 12 324 12.75 406 16.00 438 17.50 291.08 11.46 15.49 0.61 17.96 12.07
350 14 355 14.00 438 17.25 476 18.75 319.79 12.59 17.02 0.67 27.44 18.44
400 16 406 16.00 N/A N/A 527 20.75 365.51 14.39 19.32 0.76 33.73 22.66
450 18 457 18.00 N/A N/A 597 23.50 410.97 16.18 21.84 0.86 41.35 27.78
500 20 508 20.00 N/A N/A 635 25.00 456.69 17.98 24.13 0.95 48.37 32.50
  1. Other sizes and metric dimensional pipe available on request.
  2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
  3. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
  4. Jacketing 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
  5. Pressure rating of DR 21 is 552 kPa (80 psi) at 23°C (73.4°F).
  6. Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
  7. Insulation cut back for standard butt fused joint is 230 mm (9 in); other cut backs available on request. Call your Urecon representative to discuss your application requirements.
  8. Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
  9. Data may vary slightly from one pipe manufacturer to another.
  10. Reference specifications (core pipe): see pipe specifications.

Urecon Pre-Insulated HDPE Core Pipe DR 17
Dimensions 19 mm (¾ in) to 500 mm (20 in)

Nominal
Pipe Size
Outside
Pipe Dia.
Insulation O.D. DR 17, 690 kPa (100 psi)
Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
19 CTS ¾ CTS SEE DR-11
25 CTS 1 CTS SEE DR-11
40 1.5 48 1.90
139
5.50
155
6.13
42.16 1.66 2.79 0.11 1.10 0.74
50 2 60 2.375 155 6.13 165 6.50 52.83 2.08 3.55 0.14 1.34 0.90
75 3 88 3.50 171 6.75 196 7.75 77.72 3.06 5.33 0.21 2.35 1.58
100 4 114 4.50 196 7.75 228 9.00 100.07 3.94 6.86 0.27 3.53 2.37
150 6 168 6.625 247 9.75 279 11.00 147.32 5.80 9.91 0.39 6.52 4.38
200 8 219 8.625 304 12.00 336 13.25 191.77 7.55 12.95 0.51 10.46 7.03
250 10 273 10.75 355 14.00 393 15.50 239.01 9.41 16.00 0.63 15.58 10.47
300 12 324 12.75 406 16.00 438 17.50 283.46 11.16 19.05 0.75 21.28 14.30
350 14 355 14.00 438 17.25 476 18.75 318.26 12.53 20.83 0.82 30.38 20.41
400 16 406 16.00 N/A N/A 527 20.75 355.85 14.01 23.88 0.94 38.43 25.82
450 18 457 18.00 N/A N/A 597 23.50 400.30 15.76 26.92 1.06 46.26 31.08
500 20 508 20.00 N/A N/A 635 25.00 444.75 17.51 29.97 1.18 54.17 36.40
  1. Other sizes and metric dimensional pipe available on request.
  2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
  3. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
  4. Jacketing 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
  5. Pressure rating of DR 17 is 690 kPa (100 psi) at 23°C (73.4°F).
  6. Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
  7. Insulation cut back for standard butt fused joint is 230 mm (9 in); other cut backs available on request. Callyour Urecon representative to discuss your application requirements.
  8. Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
  9. Data may vary slightly from one pipe manufacturer to another.
  10. Reference specifications (core pipe): see pipe specifications.

Urecon Pre-Insulated HDPE Core Pipe DR 15.5
Dimensions 19 mm (¾ in) to 500 mm (20 in)

Nominal
Pipe Size
Outside
Pipe Dia.
Insulation O.D. DR 15.5, 690 kPa (110 psi)
Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
19 CTS ¾ CTS SEE DR-11
25 CTS 1 CTS SEE DR-11
40 1.5 SEE DR-11
50 2 SEE DR-11
75 3 88 3.50 171 6.75 196 7.75 76.70 3.02 5.84 0.23 2.47 1.66
100 4 114 4.50 196 7.75 228 9.00 98.80 3.89 7.37 0.29 3.72 2.50
150 6 168 6.625 247 9.75 279 11.00 145.28 5.72 10.92 0.43 6.97 4.68
200 8 219 8.625 304 12.00 336 13.25 189.23 7.45 14.22 0.56 11.21 7.53
250 10 273 10.75 355 14.00 393 15.50 235.71 9.28 17.52 0.69 16.76 11.26
300 12 324 12.75 406 16.00 438 17.50 279.40 11.00 20.83 0.82 22.92 15.40
350 14 355 14.00 438 17.25 476 18.75 306.57 12.07 22.86 0.90 36.45 24.49
400 16 406 16.00 N/A N/A 527 20.75 350.75 13.81 26.16 1.03 45.38 30.49
450 18 457 18.00 N/A N/A 597 23.50 394.72 15.54 29.46 1.16 56.15 37.73
500 20 508 20.00 N/A N/A 635 25.00 438.66 17.27 32.77 1.29 66.02 44.36
  1. Other sizes and metric dimensional pipe available on request.
  2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
  3. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
  4. Jacketing 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
  5. Pressure rating of DR 15.5 is 690 kPa (110 psi) at 23°C (73.4°F).
  6. Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
  7. Insulation cut back for standard butt fused joint is 230 mm (9 in); other cut backs available on request. Call your Urecon representative to discuss your application requirements.
  8. Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
  9. Data may vary slightly from one pipe manufacturer to another.
  10. Reference specifications (core pipe): see pipe specifications.

Urecon Pre-Insulated HDPE Core Pipe DR 13.5
Dimensions 19 mm (¾ in) to 500 mm (20 in)

Nominal
Pipe Size
Outside
Pipe Dia.
Insulation O.D. DR 13.5, 758 kPa (128 psi)
Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
19 CTS ¾ CTS SEE DR-11
25 CTS 1 CTS SEE DR-11
40 1.5 SEE DR-11
50 2 SEE DR-11
75 3 88 3.50 171 6.75 196 7.75 74.93 2.95 6.60 0.26 2.68 1.80
100 4 114 4.50 196 7.75 228 9.00 96.27 3.79 8.38 0.33 4.06 2.73
150 6 168 6.625 247 9.75 279 11.00 141.73 5.58 12.44 0.49 7.69 5.17
200 8 219 8.625 304 12.00 336 13.25 184.66 7.27 16.26 0.64 12.47 8.38
250 10 273 10.75 355 14.00 393 15.50 230.12 9.06 20.32 0.80 18.69 12.56
300 12 324 12.75 406 16.00 438 17.50 273.05 10.75 23.87 0.94 25.64 17.23
350 14 355 14.00 438 17.25 476 18.75 299.72 11.80 26.42 1.04 39.19 26.33
400 16 406 16.00 N/A N/A 527 20.75 342.65 13.49 30.23 1.19 48.88 32.84
450 18 457 18.00 N/A N/A 597 23.50 385.32 15.17 33.78 1.33 60.43 40.60
500 20 508 20.00 N/A N/A 635 25.00 428.24 16.86 37.59 1.48 72.11 48.45
  1. Other sizes and metric dimensional pipe available on request.
  2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
  3. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
  4. Jacketing 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
  5. Pressure rating of DR 13.5 is 758 kPa (128 psi) at 23°C (73.4°F).
  6. Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
  7. Insulation cut back for standard butt fused joint is 230 mm (9 in); other cut backs available on request. Call your Urecon representative to discuss your application requirements.
  8. Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
  9. Data may vary slightly from one pipe manufacturer to another.
  10. Reference specifications (core pipe): see pipe specifications.

Urecon Pre-Insulated HDPE Core Pipe DR 11
Dimensions 19 mm (¾ in) to 500 mm (20 in)

Nominal
Pipe Size
Outside
Pipe Dia.
Insulation O.D. DR 11, 1103 kPa (160 psi)
Insulation Thickness Avg. Pipe I.D. Min. Wall Thickness Total Weight
mm in mm in 40 mm 1.5 in 50 mm 2 in mm in mm in kg/m lbs/ft
19 CTS ¾ CTS 22,2
0.875
108
4.25
133
5.25
18.03 0.71 2.03 0.08 0.68 0.46
25 CTS 1 CTS 28,6 1.125 108 4.25 133 5.25 23.11 0.91 2.54 0.10 0.76 0.51
40 1.5 48 1.90
139
5.50
155
6.13
38.86 1.53 4.31 0.17 1.29 0.87
50 2 60 2.375 155 6.13 165 6.50 48.77 1.92 5.59 0.22 1.65 1.11
75 3 88 3.50 171 6.75 196 7.75 71.88 2.83 8.12 0.32 3.02 2.03
100 4 114 4.50 196 7.75 228 9.00 92.20 3.63 10.41 0.41 4.64 3.12
150 6 168 6.625 247 9.75 279 11.00 135.89 5.35 15.24 0.60 8.94 6.01
200 8 219 8.625 304 12.00 336 13.25 176.78 6.96 19.81 0.78 14.57 9.79
250 10 273 10.75 355 14.00 393 15.50 220.47 8.68 24.89 0.98 21.97 14.76
300 12 324 12.75 406 16.00 438 17.50 261.37 10.29 29.46 1.16 30.27 20.34
350 14 355 14.00 438 17.25 476 18.75 287.02 11.30 32.26 1.27 41.94 28.18
400 16 406 16.00 N/A N/A 527 20.75 328.17 12.92 37.08 1.46 52.33 35.16
450 18 457 18.00 N/A N/A 597 23.50 369.06 14.53 41.66 1.64 64.86 43.59
500 20 508 20.00 N/A N/A 635 25.00 410.21 16.15 46.23 1.82 76.43 51.35
  1. Other sizes and metric dimensional pipe available on request.
  2. Insulation thickness for freeze protection 50 mm (2 in) minimum; other thicknesses available on request.
  3. Insulation thickness for chilled water 40 mm (1.5 in) minimum; other thicknesses available on request.
  4. Jacketing 1.27 mm (50 mils) thick polyethylene; other types and thicknesses available on request.
  5. Pressure rating of DR 11 is 1103 kPa (160 psi) at 23°C (73.4°F).
  6. Insulated pipe available in standard industry lengths of 12.19 m (40 ft) and 15.24 m (50 ft); other lengths available on request.
  7. Insulation cut back for standard butt fused joint is 230 mm (9 in); other cut backs available on request. Call your Urecon representative to discuss your application requirements.
  8. Each pipe length shipped with suitable insulation kit for butt fused joint (unless advised otherwise).
  9. Data may vary slightly from one pipe manufacturer to another.
  10. Reference specifications (core pipe): see pipe specifications.